S.G, Bé°, C% Tester for Saline Solution TWD-150SS

Flowing liquid testing domain

  • TWD-150SS
    TWD-150SS

 

Application:Sodium chloride, zinc chloride, ammonium chloride, barium chloride, calcium chloride, magnesium chloride, sodium sulfate, ammonium sulfate, zinc sulfate,magnesium sulfate, aluminum sulfate, anhydrous copper sulfate, ammonium nitrate, zinc nitrate, sodium acetate and other production plants, research laboratories.

 
Principle: Referring to the standard regulation of GB/T611, T2423, ASTM E126, T18796, ISO 6353, by adopting the buoyancy of the object immersed in the liquid, the density and volume of the irregular weight can be used as the testing standard of saline solution;
 
 
 
Specifications:
Model
TWD-150 SS
Testing type
Specific Gravity (S.G), Baume (Bé°), Concentration (C%)
Weighing precision
0.001g
S.G range
0.0001-2.0000(glass weight)
Bé° range
0.1~80.0 Bé°
C% range
0.1%~100.0%
Standard interface
RS-232
 
 
Functions:
1. It has the compensation function of air buoyancy and the correct function of weight volume thermal expansion coefficient and temperature deviation value.
2. The temperature deviation value of Baume degree can be set.
3. According to the specific gravity value of saline solution, and then by using non-linear method, concentration can be converted.
 
Features:
1. The body is cast integrally by using aluminum alloy, the structure is stable; the unstable screen problem caused by load cell measuring influenced by pressing the key and the damage problem caused by saline solution penetrating into circuit board and sensor will not occur.                                                          
2. The measuring position and sensor are on the same platform, it can improve the defect of the measuring deviation caused by corner load.
3. The screen independent design is adopted and the screen is separated from the measuring platform, the problem of the screen damaged by saline solution corrosion and adhesion will not occur.
4. With the special hook design, and just 50CC, the saline solution S.G can be showed directly, and then Bé°, C% can be converted.
 
Key measuring points:
The best testing environment for saline solution is under the national standard reference temperature condition of 15℃,15.6℃, 20℃.

 

 

1、Liquid thermostatic device TW-01A & beaker extractor TP-28:  

 
 
 
  
 
 
 TP-28
 
 
 
Standard demonstration: please refer to catalog TW-01A 
 
 
 
 

2、Liquid thermostatic water cycling device TW-01B:

 
 
 
 
Standard demonstration: please refer to catalog TW-01B